通过软件设置实现双向直流电源的过压保护,需结合硬件监测电路与软件控制逻辑,通过实时采集电压数据、与设定阈值比较,并触发保护动作(如关断输出、调整电压或报警)。以下是具体实现步骤及关键技术要点:
c// 伪代码示例(基于STM32 HAL库)float voltage_threshold = 62.0; // 过压阈值(V)uint8_t protection_triggered = 0;while (1) { // 1. 读取ADC采样值 uint16_t adc_value = HAL_ADC_GetValue(&hadc1); float voltage = (adc_value / 4095.0) * 3.3 * 12.0; // 假设分压比1:12,参考电压3.3V // 2. 判断是否过压 if (voltage > voltage_threshold && !protection_triggered) { protection_triggered = 1; // 3. 触发保护动作 HAL_GPIO_WritePin(GPIOB, GPIO_PIN_0, GPIO_PIN_SET); // 关断输出继电器 // 可选:发送报警信号至上位机 send_alarm_message("Overvoltage Protection Triggered!"); } else if (voltage <= voltage_threshold - 1.0 && protection_triggered) { // 4. 电压恢复正常后恢复输出(可选) protection_triggered = 0; HAL_GPIO_WritePin(GPIOB, GPIO_PIN_0, GPIO_PIN_RESET); } HAL_Delay(1); // 延时1ms,控制采样周期}
c#define WINDOW_SIZE 5float voltage_buffer[WINDOW_SIZE];uint8_t buffer_index = 0;float filtered_voltage() { float sum = 0; for (int i = 0; i
模式识别
ctypedef enum { MODE_FORWARD, // 充电模式 MODE_REVERSE // 放电模式} PowerMode;void set_protection_threshold(PowerMode mode) { if (mode == MODE_FORWARD) { voltage_threshold = 62.0; // 输出过压 } else { voltage_threshold = 50.0; // 输入过压 }}
双向电流监测